HD-1004 Real-Time Personal Dust Monitor

»Home »Product Andalan »Haz-Dust »Product Haz-Dust » HD-1004 Real-Time Personal Dust Monitor

 

HD-1004

HD-1004 Real-Time Personal Dust Monitor is a completely portable package that allows true breathing zone measurements and comprehensive
graph reporting. The product is designed for aerosol and dust monitoring for industrial Hygiene and Environmental air investigations. HD-1004 is
individually worn and offers immediate determination and data storage of airborne particulate concentrations in milligrams per cubic meter. The patent pending sensor design that allows the interchange of sampling heads for inhalable, thoracic and respirable separations. The in-line disposable
cassette allows the user to simultaneously collect filter samples for further
gravimetric or chemical analysis.
The signal processing electronics and microprocessor are enclosed in a
compact case that attaches to the individual’s waist. A real-time display
reports concentrations in milligrams per cubic meter. Statistics such as:
TWA, STEL, Max and Minimum can instantly be viewed on the display.
The internal user adjustable alarm can be preset to alert the user of approaching
threshold limits.
HD-1004 can be used for a variety of applications including lead, silica,
welding fumes, pharmaceutical and construction dusts. Accompanying
software provides management ready graphs and reports. HD-1004 is an
excellent OSHA survey compliance tool for determining worker exposure
to airborne contaminants, evaluating levels of respiratory protection, or
any application that requires immediate and accurate air monitoring of
lung damaging particles.
Applications

  • Determine levels of worker respiratory protection for OSHA compliance
  •  Compliance program reviews
  • Evaluating work practices and controls of any dust generating practice
  • Safety audits
  • Can be combined with NIOSH video exposure monitoring for real-time graphical overlays and interfaces with Haz-Dust model VDM-7500
  • Welding fume exposures
  • Air quality studies in occupational health and industrial hygiene
  • Haz-Mat air quality investigation and waste site remediation
  • The Haz-Dust® IV Monitor is a useful tool for all air monitoring applications
  • Involving lung-damaging particulates

Features

  • Comfortable Light Weight  
  • Enhanced Accuracy
  • Miniaturized Sensor Design
  • RFIIEMI Protection
  • Easy to Operate
  • Data Logging
  • On Screen Display of Statistics
  • Splash-Proof
  • Optional Wireless Data Transmission
  • Adjustable Alarm Signal
  • Specifications HD-1004

    Alpha-numeric LCD-4line, 20 character
    mg/m3 concentration reading
    Four key splash proof membrane switch
    Menu driven
    NIOSH gravimetric reference
    NIST traceable – SAE fine test dust 0600 0500
    Accuracy: +/- 10% to filter gravimetric SAE dust
    Sensing range: 0.001-200 mg/m3
    Particulate size range: 0.1 to 100 μm
    Precision: +/- 0.02-mg/m3
    Sampling Flow Rate: 1.0 – 3.3 liters/minute
    Filter cassette: 37mm disposable
    Analog output: 0-2 vdc
    Alarm output: 90db at 3ft
    Recording time: 1 second to 21 weeks
    Sampling rate: 1 sec., 1 min. and 10 min.
    Data storage: 21,500 data points
    Security code: 4 digit combinations
    Memory & time storage: > 5 years
    Real-time clock and data display
    Hours, min., sec., day, month, year
    Data display: concentration in mg/ m3
    TWA, MAX, MIN, STEL, date, time
    Digital output: RS-232
    Operating temperature: 0 to 50° C
    Storage temperature: -20 to 70° C
    HazComm Software: Windows™ driven
    Power: NiMH rechargeable battery
    Operating time: > 8 hours
    Charging time: 10-12 hours
    Humidity: 95% non-condensing
    Dimensions (case): 5.4” x 3.3” x 2.7”
    Sensor Dimensions: 1.75” x 1.5”
    Weight: 1.5 lbs.


Download: /pic/HD-1004-96.pdf