6850 Double Beam Spectrophotometer

»Home »Product Andalan »BUCK SCIENTIFIC »UV/ VIS SPECTROPHOTOMETERS » 6850 Double Beam Spectrophotometer

6850 Double Beam Spectrophotometer

6850 Double Beam Spectrophotometer

• Double beam spectrophotometer with highly stable optics
• Variable spectral bandwidth 0.5, 1, 2, 4, 5nm
• Integrated user interface
• Conforms to European Pharmacopeia requirements
• Jenway Prism PC software included as standard
• Extensive range of accessories available

The new 6850 introduces the first double beam spectrophotometer with a variable spectral bandwidth into the Jenway range. The highly stable optics and two detectors measure the sample and reference simultaneously optimising measurement accuracy. The 6850 has measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA/RNA and protein analysis.

Jenway Prism PC software is supplied as standard and offers additional functionality, extensive post-measurement tools, unlimited results saving and easy export of data. The 6850 is ideal for quality control, general research, pharmaceutical, biochemical and clinical laboratory applications.

Technical Specification

Parameter

6850

Wavelength range

190 to 1100nm

Wavelength resolution

0.1nm

Wavelength accuracy

± 0.3nm (at 0.5 and 1nm bandwidth)

Wavelength reproducibility

±0.2nm

Spectral bandwidth

Variable 0.5, 1, 2, 4, 5nm

Photometric range

-0.3 to 3.0A, 0 to 200T

Photometric accuracy

± 0.002A (0-0.5A), ±0.3T (0-100T)

Photometric reproducibility

±0.001 Abs (0 to 0.5 Abs), ±0.002 Abs (0.5 to 1.0 Abs), 0.15T (0-100T)

Resolution

0.1T, 0.001A

Stray light

0.05T at 220 and 360nm

Noise

0.0005A

Stability

± 0.001Ah at 500nm after 15 min warm up

Multi-wavelength

Up to 10 wavelengths, up to 20 wavelengths with PC software

Calculations

Ratio, difference, formulae with factors

Spectrum range

Any range between 190 and 1100nm

Scan speed

100 to 2000nmmin

Scan interval

0.1, 0.2, 0.5, 1, 2 or 5nm

Kinetics

Up to 12 hours with time intervals of 0.1, 0.2, 0.5, 1, 2, 5, 10 or 30 seconds

Analysis

Slope and formula of line of best fit between any two points

Quantitation points

Up to 3 wavelengths

Quantitation Calibration

Blank with up to 10 standards or factor

Concentration range

0-99999

Calibration

Blank with standards or factor

DNA

DNA Ratio, concentration, A320 correction

Light source

Tungsten halogen and Deuterium lamps

Lamp changeover

325 to 370nm selec table

Outputs

USB and parallel

Operating system:

Windows 2000, XP, Vista, Windows 7

Electrical supply

120VA, 220110V, 5060Hz

Size (w x d x h)

600 x 450 x 200mm (23.6 x 17.7 x 7.9in)

Weight

22 kg (48.4 lbs)