GR Series Autoclave

»Home »Product Andalan »ZEALWAY »PRODUCT » GR Series Autoclave

GR Series Autoclave

Opening way: flip top
Type DA: Fully automatic, basic model
Type DF: Automatic water feeding and fast cooling based on Type DA
Type DR: Automatic drying function based on Type DF

Capacity:60L/85L/110L

Main Features

  • Dia of Sterilization chamber: The heavy-gauge sterilization chamber in a diameter of40cm offers a massiva space to satisfy various sterilization requirements.
  • Microcomputer control system: “Inspiration” fast speed Microcomputer intelligent control system ishighly robust to not only realize the total-process controls of sterilization, butalso enable convenient maintenance, inquiry, calibration ,recording and upwardscalability in the future. It allows three tiers of administrations, i.e. user,user administrator and engineer, to guarantee satisfactory use and managementof autoclave
  • Waste sterilization Mode: dedicated waste sterilization proceduresare established for effective sterilization of lab wastes.
  • Drying function: Thoroughly dryingaccording to CE standards
  • Cooling lock open temperature: Eachprocedure can set different cooling lock open temperatures according to thethermal inertia of the sterilization object so as to prevent the user fromopening the cover and hence getting burnt when the sterilizationobject(particularly liquid object) is still in an unsafe state.
  • SterilizationTemperature:105-138℃

Function

  • Mechanical interlocking:the unique “eight-column evenlydistributed” interlocking device is safer and more reliable than commoninterlocking devices
  • Electric double inner locks:enable the control system tomonitor the temperature and pressure in the sterilization chamber on areal-time basis and disable opening of the sterilization chamber cover untilthe safe temperature and pressure are reached, hence guaranteeing the personalsafety of the operator.
  • Six preset procedures:Six sterilization procedures and warming procedures are preset forthe sterilizing ,warming and drying of solids and liquids, the melting andwarming of agars. 
  • Agar processing:It can heatand melt down and preserve heat of agars or preheat the sterilization chamber.
  • Timed startup: It is possible to preset a time program so that the autoclavecan be automatically started for sterilization according to the presetschedule.
  • Memory system: The operator can set thesterilization parameters and create as many as 60 precedures that can bereadily used.
  • Steam discharge control: Upon completion ofsterilization procedure, the vent valve can automatically open to dischargesteams at the preset temperature.
  • Calibration interface:Temperature and pressurecalibration interfaces are available for calibration purpose
  • Automatic water feeding: Exempt the convenience of frequent water feeding;water level sensors are installed to automatically stop the autoclave and giveout alarms when water is running out.
  • Staurated Steam Monitoring: The system can automatically monitor the dischargeconditions of cold air so as to guarantee a sterilizing environment of puresteams and optimal sterilization effects.